Purpose

The objective of the trial is to evaluate the procedural safety and efficacy of the Medtronic TAVR system in patients with bicuspid aortic anatomy and severe aortic stenosis at low risk for SAVR

Condition

Eligibility

Eligible Ages
Over 60 Years
Eligible Genders
All
Accepts Healthy Volunteers
No

Inclusion Criteria

  1. Severe aortic stenosis, defined as follows: 1. For symptomatic patients: Aortic valve area ≤1.0 cm2 (or aortic valve area index of ≤0.6 cm2/m2), OR mean gradient ≥40 mmHg, OR Maximal aortic valve velocity ≥4.0 m/sec by transthoracic echocardiography at rest 2. For asymptomatic patients: Very severe aortic stenosis with an aortic valve area of ≤1.0 cm2 (or aortic valve area index of ≤0.6 cm2/m2), AND maximal aortic velocity ≥5.0 m/sec, or mean gradient ≥60 mmHg by transthoracic echocardiography at rest, OR Aortic valve area of ≤1.0 cm2 (or aortic valve area index of ≤0.6 cm2/m2), AND a mean gradient ≥40 mmHg or maximal aortic valve velocity ≥4.0 m/sec by transthoracic echocardiography at rest, AND an exercise tolerance test that demonstrates a limited exercise capacity, abnormal BP response, or arrhythmia OR Aortic valve area of ≤1.0 cm2 (or aortic valve area index of ≤0.6 cm2/m2), AND mean gradient ≥40 mmHg, or maximal aortic valve velocity ≥4.0 m/sec by transthoracic echocardiography at rest, AND a left ventricular ejection fraction <50%. 2. Patient is considered low risk for SAVR, where low risk is defined as predicted risk of mortality for SAVR <3% at 30 days per multidisciplinary local heart team assessment. 3. Bicuspid aortic valve anatomy (all sub-types) confirmed by MDCT. 4. The subject and the treating physician agree that the subject will return for all required post-procedure follow-up visits.

Exclusion Criteria

  1. Any condition considered a contraindication for placement of a bioprosthetic valve (eg, subject is indicated for mechanical prosthetic valve). 2. Age less than 60 years 3. A known hypersensitivity or contraindication to any of the following that cannot be adequately pre-medicated: 1. aspirin or heparin (HIT/HITTS) and bivalirudin 2. ticlopidine and clopidogrel 3. Nitinol (titanium or nickel) 4. contrast media 4. Blood dyscrasias as defined: leukopenia (WBC <1000 mm3), thrombocytopenia (platelet count <50,000 cells/mm3), history of bleeding diathesis or coagulopathy, or hypercoagulable states. 5. Ongoing sepsis, including active endocarditis. 6. Any percutaneous coronary or peripheral interventional procedure with a bare metal stent or drug eluting stent performed within 30 days prior to screening committee approval. 7. Multivessel coronary artery disease with a Syntax score >22 and/or unprotected left main coronary artery. 8. Symptomatic carotid or vertebral artery disease or successful treatment of carotid stenosis within 10 weeks of Heart Team assessment. 9. Cardiogenic shock manifested by low cardiac output, vasopressor dependence, or mechanical hemodynamic support. 10. Recent (within 2 months of Heart Team assessment) cerebrovascular accident (CVA) or transient ischemic attack (TIA). 11. Gastrointestinal (GI) bleeding that would preclude anticoagulation. 12. Subject refuses a blood transfusion. 13. Severe dementia (resulting in either inability to provide informed consent for the study/procedure, prevents independent lifestyle outside of a chronic care facility, or will fundamentally complicate rehabilitation from the procedure or compliance with follow-up visits). 14. Estimated life expectancy of less than 24 months due to associated non-cardiac co-morbid conditions. 15. Other medical, social, or psychological conditions that in the opinion of the investigator precludes the subject from appropriate consent or adherence to the protocol required follow-up exams. 16. Currently participating in an investigational drug or another device study (excluding registries). 17. Evidence of an acute myocardial infarction ≤30 days before the study procedure due to unstable coronary artery disease (WHO criteria). 18. Need for emergency surgery for any reason. 19. Subject is pregnant or breast feeding. 20. Subject is legally incompetent, or otherwise vulnerable Anatomical exclusion criteria: 21. Pre-existing prosthetic heart valve in any position. 22. Severe mitral regurgitation amenable to surgical replacement or repair. 23. Severe tricuspid regurgitation amenable to surgical replacement or repair. 24. Moderate or severe mitral stenosis amenable to surgical replacement or repair. 25. Hypertrophic obstructive cardiomyopathy with left ventricular outflow gradient. 26. Prohibitive left ventricular outflow tract calcification. 27. Sinus of Valsalva diameter unsuitable for placement of the self-expanding bioprosthesis 28. Aortic annulus diameter of <18 or >30 mm. 29. Significant ascending aortopathy requiring surgical repair 30. Ascending aorta diameter > 4.5 cm For transfemoral or transaxillary (subclavian) access: 31. Access vessel mean diameter <5.0 mm for Evolut 23R, 26R, or 29R mm TAV, or access vessel mean diameter <5.5 mm for Evolut 34R mm or Evolut PRO 23R, 26R, 29 R mm TAV. However, for transaxillary (subclavian) access in patients with a patent LIMA, access vessel mean diameter <5.5mm for Evolut 23R, 26R, or 29R mm TAV, or access vessel mean diameter <6.0 mm for the Evolut 34R or Evolut PRO TAV.

Study Design

Phase
N/A
Study Type
Interventional
Allocation
N/A
Intervention Model
Single Group Assignment
Primary Purpose
Treatment
Masking
None (Open Label)

Arm Groups

ArmDescriptionAssigned Intervention
Experimental
Medtronic TAVR Systems
Treatment of patients with bicuspid aortic anatomy and severe aortic stenosis at low risk for SAVR with Medtronic Evolut PRO and Evolut R systems
  • Device: Medtronic TAVR Systems
    Treatment of patients with bicuspid aortic anatomy and severe aortic stenosis at low risk for SAVR with Medtronic Evolut PRO and Evolut R systems

More Details

Status
Active, not recruiting
Sponsor
Medtronic Cardiovascular

Study Contact

Detailed Description

Multi-center, prospective, single arm All subjects will be treated with a Medtronic TAVR system. Subject follow-ups will be conducted at pre and post-procedure, discharge, 30 days, 1 year, and annually through 10 years

Notice

Study information shown on this site is derived from ClinicalTrials.gov (a public registry operated by the National Institutes of Health). The listing of studies provided is not certain to be all studies for which you might be eligible. Furthermore, study eligibility requirements can be difficult to understand and may change over time, so it is wise to speak with your medical care provider and individual research study teams when making decisions related to participation.